10Scene Store and GeNetix Nodes V3.1 Lockout 10Scene Wall Plates with Priorities

Please upgrade to V3.1 - take a look at this article.


  1. Find the IP of the 10Scene Store or GeNetix node using QuickQ or MagicQ Console or Rack QuickQ via Main Menu, Network Devices, MagicQ via NetManager.
  2. Connect a computer to the QuickQ network or directly to the 10Scene Store or Node.
  3. Enter the IP address from #1 in a web browser.
  4. Navigate to Device Settings, 10Scene Priority - set to "Below Input"
  5. Save

Now, when a console is seen to be outputting DMX to the 10Scene Store or Node , either via network ACN or Art-Net, or when directly plugged into the DMX 5-pin input connection or DMX input wiring, the console will be in control.


The 10Scene Wall Plates connected to the 10Scene Store or Node will be locked out. Any 10Scene Wall Station button that is active will flash red to indicate it is locked out.


When the console is disconnected or powered off and no DMX signal is detected at the DMX inputs to the 10Scene Store, or networked to the Node, the previously selected scene on the 10Scene Store or Node will be output, and the 10Scene Wall Plates will become active again.