QuickQ Console -> GeNetix - 10Scene Wall Station: Quick SetUp

  • Connect the QuickQ Console to GeNetix GN5 or GeNetix GN10 via Cat5 network cables (direct or via an unmanaged* switch).
  • Connect 10Scene Wall Plates to GeNetix via Cat5e solid core cable to Wall Plates.
  • Connect Fixtures to GeNetix via DMX cable.

GeNetix Device

  • Main Menu>Quick Setup: Set network protocol and DMX output as needed.
  • Main Menu>IP Setup: Accept default of 10.
  • Main Menu>10Scene Mode: Set to Gateway.

Consoles Settings

  • Settings>Network>wired: Accept the IP defaults, 10.0.0.X and 255.0.0.0 scheme. Check that the IP is NOT the same as the GeNetix device's.
  • Settings> DMX: For each universe, set Send Over Network to match either Art-Net or sACN, as chosen for the GeNetix device.
  • Settings>Network Devices: Use (Configure Device) to configure the GeNetix device to work for the console settings.
  • Settings>10Scene>Settings: Choose 10 scene toggles and execute 1-10 on and off AND Enable Gateways.
  • Settings>Execute: Set grid size to 10x10 and record 10scene scenes to executes first row.

*Unmanaged switch preferred. Managed may require switch configuration.